Wiring & Ranges Wiring 5 wires L1, L2, L3, N, T
  Thermal Magnetic Circuit Breaker 4 poles C16
  Rated voltage (Un) 400 Vac @ 50 Hz
  Working range From -20% Un to +10% Un
Reactive power compensation Max three-phase reactive power 10 kVA
  Manual or automatic reactive power correction from 0,5 to 10 kVAr
Consumption Standby 12 VA
  Run 90 VA
  Energy efficiency > 98,5 %
Operating conditions Temperature -10°C + 55°C
  Max altitude 2000 m above sea level
  Relative humidity 0 a 90% uncondensed
Data interface Ethernet type 100 BaseT
  Connector RJ45
Voltage inputs Number of channels 3 P +N+T
  Overloading +20% permanent
  Terminal blocks removable 7,65 mm
Current inputs from CT Number of channels 3 (L1, L2, L3)
  Transducers split core CT
  CT ratio 3000:1
  Terminal blocks removable 3,81 mm
  Rated primary current 0.1 - 200A
  Internal diameter 16 - 24 mm
  Maximum phase current (balanced) 200 Arms
  Maximum measured load (threephase balanced) 138 kVA
  Wiring calbles length 1,5 m
  Terminals plugs 5 mm
Measure Phase locked synchronous sampling Converters A/D 13 bit
  Compliance EN61557-12 (PMD_SD)
Accuracy class Voltage Class 0,5
  Current Class 1
  Active and reactive power Class 2
  Frequency Class 0,5
  Voltage and Current harmonics, THD Class 5
Clock Format yyyy/mm/dd hh:mm:ss
  Sincronization from NTP
User Interface Switch Run/Standby
  LED green POWER Power (led ON in case of correct electronics supply voltage)
  LED red WARNING Alarm (led ON in case of wrong phase sequence and/or mismatched CT coupling)
  LED green RUN led ON when reactive power correction is active (run mode active)
  LED red FAULT Fault
  LED yellow MODEM Modem status (if internal modem installed)
Safety Standard EN61010-1
  Voltage inputs CAT III / 300 V
  IP degree IP44, IP55 on request
  Terminals IP20 (EN60529), IP55 on frequest
EMC Emissions EN61000–6–4
  Immunity EN61000–6–2
Enclosure Size 320 x 550 x 200 mm
  Material Metal
  Weight 20 Kg
Reliability MTBF 33 years
  Avg. lifetime 8 years

News

  • TeamWare at Key Energy 2025
    10 February 2025
  • TeamWare is the CCI official supplier of AMON Energy
    4 December 2024

GREEN LAB ENGINEERING

For reactive power compensation in industrial plants.

Is a TEAMWARE project

  • Privacy Policy
  • Cookie Policy

Contacts

TW-TeamWare S.r.l. Via Pindaro 19 20128 Milan - ITALY

Send us an e-mail

contact us +39 02 27003261

Condizioni di vendita B2B
TW-TeamWare S.r.l. - Via Pindaro, 19 - 20128 Milano ITALY - Cap. Soc. € 100.000 i.v. - P.IVA, C.F. e Reg. Imprese IT 12305840154 - R.E.A. MI-1545453
RAEE IT19050000011341
D-U-N-S ® Number: 428130678 - PEC tw@pec.teamware.it - Azienda certificata ISO9001:2015-ISO14001:2015-ISO45001:2018-ISO27001:2022
Webdesign and development MADE