{"id":649,"date":"2016-04-19T18:55:16","date_gmt":"2016-04-19T16:55:16","guid":{"rendered":"http:\/\/www.teamware.it\/sito\/en\/product\/wally-a3\/"},"modified":"2017-06-26T11:05:09","modified_gmt":"2017-06-26T09:05:09","slug":"wally-a3","status":"publish","type":"portfolio","link":"https:\/\/www.teamware.it\/en\/product\/wally-a3\/","title":{"rendered":"Wally A3"},"content":{"rendered":"<h3>HIGH PERFORMANCE<br \/>\nPOWER QUALITY ANALYZER<\/h3>\n<p>Class A according to IEC61000-4-30 Ed. 3<br \/>\nClass 0.1 for energy meter<\/p>\n<ul>\n<li>ENEL EA 0500<\/li>\n<li>EN61000-4-30 Ed. 3 Class A<\/li>\n<\/ul>\n<div class=\"jq-tabs tabs_wrapper tabs_vertical\"><ul><li><a href=\"#tab-6ada85b1070a0-1\">GENERAL FEATURES<\/a><\/li><li><a href=\"#tab-6ada85b1070a0-2\">SPECIFICATIONS<\/a><\/li><li><a href=\"#tab-6ada85b1070a0-3\">AREA DOWNLOAD<\/a><\/li><\/ul><div id=\"tab-6ada85b1070a0-1\" ><br \/>\n<strong>Applications<\/strong><br \/>\nLV\/MV\/HV electric systems<\/p>\n<p><strong>Functions<\/strong><br \/>\nThree phase high-precision analyzer and recorder, PowerQuality, PowerMeter, Fault Recorder, Energy meter<\/p>\n<p><strong>Measures<\/strong><\/p>\n<ul>\n<li>Voltages and Currents<\/li>\n<li>Active, Reactive and Apparent power<\/li>\n<li>Active and Reactive (4 quadrants) Energy<\/li>\n<li>Power Factor<\/li>\n<li>Frequency<\/li>\n<li>Flicker (Pst e Plt)<\/li>\n<li>Voltages and Currents Harmonics and Interharmonics (up to 50\u00b0 order)<\/li>\n<li>Voltage Unbalance<\/li>\n<li>Voltage Dips and Swells<\/li>\n<li>Voltage Interruptions (short and long)<\/li>\n<li>Rapid Voltage Changes<\/li>\n<li>Waveforms (window records with programmable Pre and Post-Triggers<\/li>\n<\/ul>\n<p><strong>Accuracy<\/strong><br \/>\nAccording to IEC61000-4-30 Ed. 3 Class A<br \/>\nand IEC62053-22-30 Class 0.1<\/p>\n<p><strong>Safety<\/strong><br \/>\nCAT IV 600V, class 2 (double insulation) for voltage and direct current measuring circuits<\/p>\n<p><strong>Certification<\/strong><br \/>\nIEC61000-4-30 Ed. 3 Class A<\/p>\n<p><strong>Approval<\/strong><br \/>\nApproved according to ENEL EA 0500 specification \u201cApparecchiature portatili per la registrazione delle grandezze elettriche nelle reti di distribuzione\u201d<\/p>\n<p><strong>The most compact analyzer on the market, with full equipment of integrated resources<\/strong><\/p>\n<ul>\n<li>4 voltage channels 0\u00f7400Vac<\/li>\n<li>3 current channels 0\u00f75Aac<\/li>\n<li>4 channels for current transducers with voltage output 0\u00f73Vac\/dc<\/li>\n<li>4 input channels for flexible Rogowski coils<\/li>\n<li>Internal storage memory 2GB (expandable to 16GB)<\/li>\n<li>1 mini USB 2.0 (device) port<\/li>\n<li>1 USB 1.1 (host) port<\/li>\n<li>1 Ethernet 100baseT port<\/li>\n<li>1 GPS receiver port (optional)<\/li>\n<li>1 insulated digital I\/O port (2IN + 1OUT)<\/li>\n<li>Auxiliary supply ranges:<br \/>\n40-130Vac or 80-260Vac\/dc (100\/\u221a3 Vac with external optional adapter)<\/li>\n<li>Internal UPS for more than 40 minutes backup supply<\/li>\n<li>HMI with graphic WQVGA color display, functional keys and signalling leds<\/li>\n<li>Internal GSM\/GPRS modem<\/li>\n<li>Pulse emitting leds for active and reactive energy accuracy test<\/li>\n<li>Size: 250 x 150 x 70 mm<\/li>\n<li>Weight: Kg 1.5<\/li>\n<\/ul>\n<p><em>For further information, please download our technical data sheet (DOWNLOAD AREA, left sidebar)<\/em><br \/>\n<\/div><div id=\"tab-6ada85b1070a0-2\" ><br \/>\n<strong>Power Supply<\/strong><br \/>\nVoltage: 40\u00f7130Vac \u2013 80\u00f7260 Vac\/dc &#8211; 50\/60Hz<br \/>\nPower consumptions: 20 VA<br \/>\nBattery: 12 V 0.8Ah Pb sealed<br \/>\nBattery operating time: 40 minutes, self-limited<\/p>\n<p><strong>Voltage input channels<\/strong><br \/>\nChannels: 4<br \/>\nSingle range up to 600 Vac\/dc<br \/>\nPermanent overload: +100%<br \/>\nType: resistor network<br \/>\nImpedance: 1 Mohm<br \/>\nPluggable terminal blocks pitch 7,62 mm<\/p>\n<p><strong>Direct input Current channels<\/strong><br \/>\nChannels: 3<br \/>\nRange: 0\u00f75 Aac<br \/>\nPermanent overload: +100%<br \/>\nType: internal current transformer<br \/>\nPluggable terminal blocks pitch 7,62 mm<\/p>\n<p><strong>Current channels from transducers<\/strong><br \/>\nChannels: 4<br \/>\nRange: 0\u00f73 Vac\/dc (0\u00f77 Vac\/dc on request)<br \/>\nPermanent overload: +50%<br \/>\nType: resistor network<br \/>\nImpedance: 1 Mohm<br \/>\nPluggable terminal blocks pitch 3.81 mm<\/p>\n<p>C<strong>urrent channels from Rogowski transducers<\/strong><br \/>\nChannels: 4<br \/>\nRange: 0\u00f7300 Iac and 0\u00f73000 Iac<br \/>\nRogowski coil lenght: 500mm (\u00d8 159mm) &#8211; 600mm (\u00d8 191mm)<\/p>\n<p><strong>Measurement method<\/strong><br \/>\nSynchronous sampling with phase locking<br \/>\nBandwidth: -3dB @ 6,4 kHz<br \/>\nA\/D converter resolution: 16 bit<br \/>\nSample rate: 25,6 ksample\/sec.<br \/>\nCompliance: EN61000-4-30 Ed. 3 Class A<\/p>\n<p><strong>Accuracy (@25 \u00b0C, 45-65Hz)<\/strong><br \/>\nVoltage: \u00b10.1% Udin from 10% to 150% Udin<br \/>\nCurrent: \u00b10.1% Idin from 10% to 150% Idin<br \/>\nFrequency: \u00b10.01% reading<br \/>\nHarmonics: \u00b10.5 reading for THD &gt; 0.5%<br \/>\nDerived measures: \uf0b10.2% from 10% to 150% of<br \/>\nUdin x Idin<br \/>\nEnergy: Active Class 0.1 &#8211; Reactive Class 0.5<br \/>\n(test methods according to 0.2S IEC 62053-22)<\/p>\n<p><strong>Digital Input\/Output<\/strong><br \/>\n2 insulated digital inputs<br \/>\n1 insulated optomos digital output<\/p>\n<p><strong>User interface<\/strong><br \/>\nDisplay: color graphic display WQVGA<br \/>\nKeyboard: n. 6 functional keys<br \/>\nLed: On, Battery status, Modem status<br \/>\nBattery charge indication (5 leds)<\/p>\n<p><strong>Ethernet Port<\/strong><br \/>\nType: 100baseT<br \/>\nConnector: RJ45<\/p>\n<p><strong>USB 1 Port<\/strong><br \/>\nType: Host 1.1<br \/>\nInterface for: external storage media, Wi-Fi communication adapter, external modem<\/p>\n<p><strong>USB 2 Type<\/strong><br \/>\nType: Device 2.0<br \/>\nPersonal Computer data interface<\/p>\n<p><strong>Clock-Calendar<\/strong><br \/>\nFormat: yyyy\/mm\/dd hh:mm:ss.msec<br \/>\nAccuracy: better than 1 second\/day without GPS &#8211; better than 16.67 ms\/day from UTC with GPS<br \/>\nExternal time synchronization sources: GPS receiver mod GTS9000 (optional)<\/p>\n<p><strong>Enclosure <\/strong><br \/>\nSize: 250 x 150 x 70 mm<br \/>\nEnclosure: ABS<br \/>\nWeight: 1,5 Kg<br \/>\nSealable terminal compartments<\/p>\n<p><strong>Safety<\/strong><br \/>\nMeets EN61010-1<br \/>\nDouble insulated power supply<br \/>\nVoltage and current inputs: CAT IV \/ 600V class 2 (double insulation)<br \/>\nDegree of protection: IP40 (connection compartment IP20)<\/p>\n<p><strong>EMC<\/strong><br \/>\nEmissions: EN61000-6-3 (residential)<br \/>\nImmunity: EN61000-6-2 (industrial) and EN61236-1<\/p>\n<p><strong>Environmental conditions<\/strong><br \/>\nOperating temperature: -10 \u00f7 +50 \u00b0C<br \/>\nStorage temperature: -25 \u00f7 +60 \u00b0C<br \/>\nHumidity: 85% non-condensing<\/p>\n<p><strong>Transport case<\/strong><br \/>\nHard case IP65 black color, with compartments for accessories.<br \/>\nSize: 465 x 365 x 180 mm<\/p>\n<p><strong>GSM\/GPRS Modem (option)<\/strong><br \/>\nModem type: Internal, Quadband 850\/900\/1800\/1900 MHz<br \/>\nNetworking: GSM and GPRS<br \/>\nInternal antenna<br \/>\nOptional external antenna<br \/>\nSealable SIM holder<\/p>\n<p><strong>GTS 9000 GPS receiver (option)<\/strong><br \/>\nGPS receiver for time synchronization (antenna must be placed outside)<\/p>\n<p><strong>Clamps current transducers (option)<\/strong><br \/>\nWide choice of clamp current transducers with current output (\/5A) or voltage output \/3V) or Rogowski coils ranging from 10 A to 3000 A<\/p>\n<p><em>For further information, please download our technical data sheet (DOWNLOAD AREA, left sidebar)<\/em><br \/>\n<\/div><div id=\"tab-6ada85b1070a0-3\" ><\/p>\n<p>Please download our technical data sheet.<\/p>\n<p>\n<div class=\"wp-block-button\">\n<a  data-e-Disable-Page-Transition=\"true\" class=\"dlm-download-link dlm-download-button wp-block-button__link wp-element-button\" title=\"\" href=\"https:\/\/www.teamware.it\/en\/download\/1276\/?tmstv=1792705969\" rel=\"nofollow\" id=\"download-link-1276\" data-redirect=\"false\" >\n\tDownload &ldquo;tw_wally_a3_eng.pdf&rdquo;\t<span class=\"dlm-button-meta\">tw_wally_a3_eng.pdf\t\t&ndash; <span\n\t\t\tclass=\"dlm-download-count-value\"\n\t\t\tdata-count-format=\"times\">Downloaded 1864 times<\/span>\n\t\t&ndash; 398.67 KB<\/span>\n<\/a>\n<\/div>\n<\/div><\/div>\n<h3>Gallery<\/h3>\n<hr class=\" hr_color\" style=\"margin:0 auto 30px;\"\/>\n\n\n","protected":false},"excerpt":{"rendered":"<p>HIGH PERFORMANCE POWER QUALITY ANALYZER Class A according to IEC61000-4-30 Ed. 3 Class 0.1 for energy meter ENEL EA 0500 EN61000-4-30 Ed. 3 Class A Gallery<\/p>\n","protected":false},"author":1,"featured_media":2803,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"portfolio-types":[31],"class_list":["post-649","portfolio","type-portfolio","status-publish","has-post-thumbnail","hentry","portfolio-types-qualita-della-fornitura-en"],"_links":{"self":[{"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/portfolio\/649","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/types\/portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/comments?post=649"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/media\/2803"}],"wp:attachment":[{"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/media?parent=649"}],"wp:term":[{"taxonomy":"portfolio-types","embeddable":true,"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/portfolio-types?post=649"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}