{"id":644,"date":"2016-04-19T19:02:38","date_gmt":"2016-04-19T17:02:38","guid":{"rendered":"http:\/\/www.teamware.it\/sito\/en\/product\/up-2016\/"},"modified":"2022-08-19T12:08:24","modified_gmt":"2022-08-19T10:08:24","slug":"up2008-up16","status":"publish","type":"portfolio","link":"https:\/\/www.teamware.it\/en\/product\/up2008-up16\/","title":{"rendered":"UP2015-UP16"},"content":{"rendered":"<h3>SECONDARY SUBSTATIONS\u00a0REMOTE CONTROL AND MONITORING DEVICE<\/h3>\n<p>In compliance with Enel <strong><em>GSTR001\/1 e GSTR001\/2<\/em><\/strong><\/p>\n<div class=\"jq-tabs tabs_wrapper tabs_vertical\"><ul><li><a href=\"#tab-6ad0126dca733-1\">GENERAL INFORMATION<\/a><\/li><li><a href=\"#tab-6ad0126dca733-2\">TECHNICAL FEATURES<\/a><\/li><li><a href=\"#tab-6ad0126dca733-3\">DOWNLOAD AREA<\/a><\/li><\/ul><div id=\"tab-6ad0126dca733-1\" ><br \/>\nThe UP2015-UP16 is remote control Peripheral Unit for secondary substations and Medium Voltage (MV) power distribution system<\/p>\n<p>Main functions of the UP2015-UP16 are:<\/p>\n<ul>\n<li>Remote control and Automation of Secondary substation switchgear<\/li>\n<li>Permanent Fault detection<\/li>\n<li>Monitoring of Medium Voltage Power Grid<\/li>\n<\/ul>\n<p>The UP2015-UP16 allows to create the comunication system between field and The Distribution Control Centre. In particular:<\/p>\n<ul>\n<li>Receiving and carrying out commands sent by the Distribution Control Centre (Remote Control).<\/li>\n<li>Send field collected informations (remote signaling and telemetry) to the Distribution Control Centre side<\/li>\n<\/ul>\n<p>These functions allow to guarantee Reliability Hight Level of Electric Power Distribution system, reducing the number and duration of power outages caused by circuit faults.<\/p>\n<p>Furthermore, Remote Control permits optimization of electric power distribution system maintenance and planning policies.<\/p>\n<p>The UP2015-UP16 is made by two components integrated in a metal cabinet:<\/p>\n<ul>\n<li><strong>The UE16 module<\/strong>: is the unit of data acquisition, monitoring, transmission, and processing. The UE16 is the field interface also. The UE16 is completely remote programmable by personal computer.<\/li>\n<li><strong>The ACB module<\/strong>: includes a power supply and a battery system with charger circuit . The ACB supplies the power to UE16, to comunication device called DCE and to motors of Switchgear connected to the UP. The Battery system is made by two Lead-acid battery and the ACB monitors his functional states. The DCE is completely programmable from personal computer by local comunication port.<\/li>\n<\/ul>\n<p><strong>Main features<\/strong><\/p>\n<p>Extensive range regarding Remote Control of Electric Power Distribution System features.<\/p>\n<p>Acquisition, processing and collection of the Switchgear states.<\/p>\n<p>Managing of fault-detection automation<\/p>\n<p>Archiving of electric power distribution system data management and of chronological events (fault, tension failure, exc) trend.<\/p>\n<p>Processing of field signals correlation for generating signs to the \u00a0Distribution Control Centre.<\/p>\n<p>Validation and dispatch of commands from the the Distribution Control Centre to Switchgear.<\/p>\n<p>Comunication with the Distribution Control Centre technologies:<\/p>\n<ul>\n<li>GSM\/GPRS\/UMTS<\/li>\n<li>Public Switched Telephone Network (PSTN)<\/li>\n<li>Network LAN\/WAN IP based<\/li>\n<\/ul>\n<p>Comunication Protocols:<\/p>\n<ul>\n<li>IEC 60870-5-101<\/li>\n<li>IEC 60870-5-104<\/li>\n<\/ul>\n<p>Management of diagnostic of failure devices with emission of local and remote warnings<\/p>\n<p>Monitoring of Secondary Substation temperature throuth dedicated sensor and managing of \u00a0door opening warning.<\/p>\n<p>Power supply to the automation components of\u00a0 secondary substation.<\/p>\n<p><\/div><div id=\"tab-6ad0126dca733-2\" ><\/p>\n<h4>The UE16 Module<\/h4>\n<p><strong>Input\/output Interface<\/strong><\/p>\n<p><strong>89 Remote signals (TS): <\/strong><\/p>\n<ul>\n<li>galvanically optocoupled digital input<\/li>\n<li>sampling: 10msec<\/li>\n<\/ul>\n<p><strong>32 Remote commands (TC): <\/strong><\/p>\n<ul>\n<li>Relay output with 1 \/ N of the uniqueness control of the carring out, execution policy in double safety and evaluation of the value of the output load impedance.<\/li>\n<li>nominal current : 5A<\/li>\n<li>interruption rate: 0,5A a 110 Vcc con L\/R = 40msec.<\/li>\n<\/ul>\n<p><strong>16 Telemetry (TM):<\/strong><\/p>\n<ul>\n<li>differential analog inputs galvanically isolated<\/li>\n<li>input impedance: 50ohm<\/li>\n<li>measure range: \u00b1 5mA e 4-20mA<\/li>\n<li>precision: 1%FS<\/li>\n<li>resolution: 12bit<\/li>\n<\/ul>\n<p><strong>16 Digital Outputs (UD):<\/strong><\/p>\n<ul>\n<li>open collector (source) output galvanically isolated (max current 50mA)<\/li>\n<\/ul>\n<p><strong><u>Communication ports<\/u><\/strong><\/p>\n<p>There are three comunication ports:<\/p>\n<ul>\n<li>1 Ethernet Port 10\/100BaseT (available both as LAN\/WAN interface and as configuration and local monitoring port)<\/li>\n<li>1 serial Port V.24 (interface to external DCE device dedicated)<\/li>\n<li>1 USB 2.0 device Port (configuration and local monitoring dedicated)<\/li>\n<\/ul>\n<p><strong><u>Power Supply<\/u><\/strong><\/p>\n<p>The UE16 module is powered by the main source with:<\/p>\n<ul>\n<li>Nominal voltage: 24Vcc \u00b120%<\/li>\n<\/ul>\n<p>The Hardware is powered by the secondary source galvanically isolated from the main.<\/p>\n<p><strong><u>Visual indicators<\/u><\/strong><\/p>\n<p>There are three leds signs:<\/p>\n<ul>\n<li>Fatal failure<\/li>\n<li>General anomaly<\/li>\n<li>Main source presence<\/li>\n<\/ul>\n<p><strong><u>Connections<\/u><\/strong><\/p>\n<ul>\n<li>Ethernet interface: RJ45 connector<\/li>\n<li>V.24 serial interface: DB25 connector with male poles<\/li>\n<li>USB local interface: B type connector<\/li>\n<li>16 female connectors with 9 poles for connections to RG device<\/li>\n<li>16 female connectors with 12 poles for connections to Switchgear<\/li>\n<li>1 female connector with 12 pole for connections to the ACB module<\/li>\n<li>2 extractable terminal boards with 16 poles for connections to remote signals (TS)<\/li>\n<li>2 extractable terminal boards with 16 poles for connections to Telemetry<\/li>\n<li>1 extractable terminal with 4 poles for connections to temperature sensor of the substation<\/li>\n<li>1 extractable terminal with 4 poles for connections to particular remote signals :\n<ul>\n<li>Door Opening<\/li>\n<li>IMS TR Opening<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><strong><u>Mechanical features<\/u><\/strong><\/p>\n<p>The modules are contained in a standard rack box 19\u201d 7U<\/p>\n<h4>The ACB Module<\/h4>\n<p>Main electric features are:<\/p>\n<p><em><u>Main source voltage:\u00a0<\/u><\/em>100\/230 V<sub>AC<\/sub> (-10%\u00f7+20%),\u00a0setting up by dedicated selector.<\/p>\n<p><em><u>Nominal frequency<\/u><\/em>: 50\/60Hz<\/p>\n<p><em><u>Power<\/u><\/em>: 150W<\/p>\n<p>The secondary power sources are:<\/p>\n<p><em><u>Output of battery charger and load powered:<\/u><\/em><\/p>\n<ul>\n<li>Nominal Voltage: 24V<sub>DC<\/sub> set between 23 and 28 V<sub>DC<\/sub> balanced also in function of the temperature of the battery<\/li>\n<li>Maximum available current (fixed): 5A \u00b15%<\/li>\n<\/ul>\n<p><em><u>Auxiliary output power supply:<\/u><\/em><\/p>\n<ul>\n<li>Nominal Tension: 12 V<sub>DC<\/sub><\/li>\n<li>Maximum available current (fixed): 1A<\/li>\n<\/ul>\n<p><em><u>Whole efficiency:<\/u><\/em><\/p>\n<p>\u226575% \u00b1 3%<\/p>\n<p>(calculated at maximum supplied current 5A and at nominal voltage of \u00a024V<sub>DC<\/sub>)<\/p>\n<p><em><u>Visual indicators<\/u><\/em><\/p>\n<p>There are five leds signs:<\/p>\n<ul>\n<li>Main source presence<\/li>\n<li>Secondary source presence<\/li>\n<li>Secondary tension low level<\/li>\n<li>Secondary tension maximum level<\/li>\n<li>Battery failure<\/li>\n<\/ul>\n<p><em><u>Connection and optionals<\/u><\/em><\/p>\n<ul>\n<li>USB local interface: type B connector<\/li>\n<li>1 female connector with 9 poles for connection to batteries and external modem<\/li>\n<li>1 female connector with 12 poles for connection to verso the UE8 module<\/li>\n<li>1 three-poles socket for the main power supply<\/li>\n<li>1 bipolar circuit breaker for IO: 2A type loads<\/li>\n<li>1 Thermal magnetic circuit breaker with auxiliary contact: 20A C curve<\/li>\n<li>2 fuse holders with fuses of main grid protection: 3,15AT.<\/li>\n<li>1 fuse holder with fuse 20AT of battery output protection<\/li>\n<\/ul>\n<p><em><u>Mechanical features<\/u><\/em><\/p>\n<p>The modules are contained in a standard rack box 19\u201d 3U<\/p>\n<p><strong>EMC<\/strong><br \/>\nEmissions<\/p>\n<ul>\n<li>EN55022 Class A<\/li>\n<\/ul>\n<p>Immunity<\/p>\n<ul>\n<li>EN61000-4-8: Level 5<\/li>\n<li>EN61000-4-10: Level 4<\/li>\n<li>EN61000-4-3: Level 4<\/li>\n<li>ENV50204: Level 4<\/li>\n<li>EN61000-4-2: Level 4<\/li>\n<li>EN61000-4-16: Level 3<\/li>\n<li>EN61000-4-6: Level 3<\/li>\n<li>EN61000-4-12: Level 3<\/li>\n<li>EN61000-4-18: Level 3<\/li>\n<li>EN61000-4-4: Level 3<\/li>\n<li>EN61000-4-5: Level 3<\/li>\n<\/ul>\n<p><strong>Environmental conditions<\/strong><br \/>\nOperating temperature: -10\u00f7 +55\u00b0C<br \/>\nStorage temperature: -25\u00f7 +70\u00b0C<br \/>\nHumidity: 93%<\/p>\n<p><strong>IP Grade<\/strong><\/p>\n<p>EN60529-1 compliant: IP30<\/p>\n<p><strong>Configuration software<\/strong><\/p>\n<p>UP2015-UP16 is accompanied by a configuration application program that runs under Windows \u00a9. It allows the configuration of the UP both remotely and locally.<br \/>\nLocal configuration must be performed with a personal computer, connected to the UP via USB 2.0 or through an Ethernet interface.<br \/>\nThe application allows to define:<\/p>\n<ul>\n<li>The general parameters of operation of the device<\/li>\n<li>Communication parameters<\/li>\n<li>The characteristics of the OdMs connected to the UP<\/li>\n<li>Remote Signals, Remote Measures and the Digital outputs.<\/li>\n<\/ul>\n<p>Furthermore, it is a useful diagnostic and verification tool, as it allows:<\/p>\n<ul>\n<li>Monitoring the status of the inputs and outputs<\/li>\n<li>Monitoring, with the possibility of saving on file, the states of the automatisms, their transitions and the corresponding values assumed by the physical and logical inputs.<\/li>\n<li>Sending commands to the instantiated OdMs.<\/li>\n<\/ul>\n<p>It is also possible to analyze the recordings at a later time.<\/p>\n<p><\/div><div id=\"tab-6ad0126dca733-3\" ><\/p>\n<p>Please download our technical data sheet (also available in Romanian).<\/p>\n<p>\n<div class=\"wp-block-button\">\n<a  data-e-Disable-Page-Transition=\"true\" class=\"dlm-download-link dlm-download-button wp-block-button__link wp-element-button\" title=\"\" href=\"https:\/\/www.teamware.it\/en\/download\/1629\/?tmstv=1792021101\" rel=\"nofollow\" id=\"download-link-1629\" data-redirect=\"false\" >\n\tDownload &ldquo;UP2015-UP16 datasheet - eng&rdquo;\t<span class=\"dlm-button-meta\">tw_UP2015_UP16_eng-rev1.pdf\t\t&ndash; <span\n\t\t\tclass=\"dlm-download-count-value\"\n\t\t\tdata-count-format=\"times\">Downloaded 1327 times<\/span>\n\t\t&ndash; 439.12 KB<\/span>\n<\/a>\n<\/div>\n<\/p>\n<p>\n<div class=\"wp-block-button\">\n<a  data-e-Disable-Page-Transition=\"true\" class=\"dlm-download-link dlm-download-button wp-block-button__link wp-element-button\" title=\"\" href=\"https:\/\/www.teamware.it\/en\/download\/1633\/?tmstv=1792021101\" rel=\"nofollow\" id=\"download-link-1633\" data-redirect=\"false\" >\n\tDownload &ldquo;UP2015-UP16 datasheet - ro&rdquo;\t<span class=\"dlm-button-meta\">tw_UP2015_UP16_ro-rev1.pdf\t\t&ndash; <span\n\t\t\tclass=\"dlm-download-count-value\"\n\t\t\tdata-count-format=\"times\">Downloaded 1203 times<\/span>\n\t\t&ndash; 541.76 KB<\/span>\n<\/a>\n<\/div>\n<\/p>\n<p><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>SECONDARY SUBSTATIONS\u00a0REMOTE CONTROL AND MONITORING DEVICE In compliance with Enel GSTR001\/1 e GSTR001\/2<\/p>\n","protected":false},"author":1,"featured_media":1627,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"portfolio-types":[32],"class_list":["post-644","portfolio","type-portfolio","status-publish","has-post-thumbnail","hentry","portfolio-types-telecontrollo-reti-en"],"_links":{"self":[{"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/portfolio\/644","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/types\/portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/comments?post=644"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/media\/1627"}],"wp:attachment":[{"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/media?parent=644"}],"wp:term":[{"taxonomy":"portfolio-types","embeddable":true,"href":"https:\/\/www.teamware.it\/en\/wp-json\/wp\/v2\/portfolio-types?post=644"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}